{"product_id":"baterie-ecosolex-esr-l5000a","title":"Baterie ECOSOLEX ESR-L5000A","description":"\u003ch3 data-path-to-node=\"1\" style=\"text-align: center;\"\u003eDescrierea Produsului\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003eBateria este proiectată sub formă de modul montabil în rack, oferind o soluție compactă și eficientă pentru stocarea energiei solare. Principalele sale avantaje includ:\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eSiguranță ridicată:\u003c\/b\u003e Utilizează celule LFP (LiFePO4) recunoscute pentru stabilitatea termică și durata lungă de viață.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eModularitate:\u003c\/b\u003e Designul permite conectarea în paralel a mai multor unități pentru a crește capacitatea totală de stocare în funcție de necesități.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eSistem de Management (BMS) Inteligent:\u003c\/b\u003e Protejează bateria împotriva supraîncărcării, descărcării excesive și temperaturilor extreme.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCompatibilitate:\u003c\/b\u003e Este compatibilă cu majoritatea invertoarelor hibride de joasă tensiune de pe piață.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"1\" style=\"text-align: center;\"\u003eParametri Tehnici\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"2\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParametru\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eValoare \/ Detalii\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,1,0,0\"\u003e\u003cb data-path-to-node=\"2,1,0,0\" data-index-in-node=\"0\"\u003eTensiune Nominală\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,1,1,0\"\u003e51.2V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,2,0,0\"\u003e\u003cb data-path-to-node=\"2,2,0,0\" data-index-in-node=\"0\"\u003eCapacitate Nominală\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,2,1,0\"\u003e100Ah\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,3,0,0\"\u003e\u003cb data-path-to-node=\"2,3,0,0\" data-index-in-node=\"0\"\u003eEnergie Nominală @0.2C\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,3,1,0\"\u003e5.12kWh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,4,0,0\"\u003e\u003cb data-path-to-node=\"2,4,0,0\" data-index-in-node=\"0\"\u003eEnergie Utilizabilă @0.2C\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,4,1,0\"\u003e4.92kWh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,5,0,0\"\u003e\u003cb data-path-to-node=\"2,5,0,0\" data-index-in-node=\"0\"\u003eInterval Tensiune de Operare\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,5,1,0\"\u003e48V~56V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,6,0,0\"\u003e\u003cb data-path-to-node=\"2,6,0,0\" data-index-in-node=\"0\"\u003eTensiune de Încărcare\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,6,1,0\"\u003e56V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,7,0,0\"\u003e\u003cb data-path-to-node=\"2,7,0,0\" data-index-in-node=\"0\"\u003eTensiune de Menținere (Float)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,7,1,0\"\u003e54.6V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,8,0,0\"\u003e\u003cb data-path-to-node=\"2,8,0,0\" data-index-in-node=\"0\"\u003eCurent Standard de Încărcare\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,8,1,0\"\u003e50A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,9,0,0\"\u003e\u003cb data-path-to-node=\"2,9,0,0\" data-index-in-node=\"0\"\u003eCurent Maxim de Încărcare\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,9,1,0\"\u003e70A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,10,0,0\"\u003e\u003cb data-path-to-node=\"2,10,0,0\" data-index-in-node=\"0\"\u003eCurent Standard de Descărcare\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,10,1,0\"\u003e50A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,11,0,0\"\u003e\u003cb data-path-to-node=\"2,11,0,0\" data-index-in-node=\"0\"\u003eCurent Maxim de Descărcare\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,11,1,0\"\u003e100A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,12,0,0\"\u003e\u003cb data-path-to-node=\"2,12,0,0\" data-index-in-node=\"0\"\u003eComunicare\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,12,1,0\"\u003eRS485 \/ CAN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,13,0,0\"\u003e\u003cb data-path-to-node=\"2,13,0,0\" data-index-in-node=\"0\"\u003eCurent de Descărcare de Vârf\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,13,1,0\"\u003e\u0026lt;119A@5min, \u0026lt;200A@15s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,14,0,0\"\u003e\u003cb data-path-to-node=\"2,14,0,0\" data-index-in-node=\"0\"\u003eGrad de Protecție (IP)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,14,1,0\"\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,15,0,0\"\u003e\u003cb data-path-to-node=\"2,15,0,0\" data-index-in-node=\"0\"\u003eCiclu de Viață\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,15,1,0\"\u003e≥6000 cicluri, @25°C, @0.2C, @90%DOD, @60%EOL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,16,0,0\"\u003e\u003cb data-path-to-node=\"2,16,0,0\" data-index-in-node=\"0\"\u003eGreutate Netă\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,16,1,0\"\u003e≈46kg (101.4 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,17,0,0\"\u003e\u003cb data-path-to-node=\"2,17,0,0\" data-index-in-node=\"0\"\u003eDimensiuni (L\u003ci data-path-to-node=\"2,17,0,0\" data-index-in-node=\"13\"\u003eH\u003c\/i\u003eD)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,17,1,0\"\u003e482\u003ci data-path-to-node=\"2,17,1,0\" data-index-in-node=\"3\"\u003e133.5\u003c\/i\u003e460mm (18.9\u003ci data-path-to-node=\"2,17,1,0\" data-index-in-node=\"19\"\u003e5.2\u003c\/i\u003e18.1 inch)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,18,0,0\"\u003e\u003cb data-path-to-node=\"2,18,0,0\" data-index-in-node=\"0\"\u003eTip Celulă\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,18,1,0\"\u003eLitiu-Fier-Fosfat (LiFePO₄)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,19,0,0\"\u003e\u003cb data-path-to-node=\"2,19,0,0\" data-index-in-node=\"0\"\u003eInterval Temperatură Operare\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,19,1,0\"\u003eÎncărcare 0~50°C, Descărcare -10~50°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,20,0,0\"\u003e\u003cb data-path-to-node=\"2,20,0,0\" data-index-in-node=\"0\"\u003eTemperatură de Depozitare\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,20,1,0\"\u003e(5~90%RH): ≤3 luni: -10°C\u0026lt;T\u0026lt;45°C, \u0026gt;3 luni: 15~35°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,21,0,0\"\u003e\u003cb data-path-to-node=\"2,21,0,0\" data-index-in-node=\"0\"\u003eUmiditate Relativă\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,21,1,0\"\u003e5%~90%, Fără Condens\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,22,0,0\"\u003e\u003cb data-path-to-node=\"2,22,0,0\" data-index-in-node=\"0\"\u003eAltitudine Instalare\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,22,1,0\"\u003e≤4000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,23,0,0\"\u003e\u003cb data-path-to-node=\"2,23,0,0\" data-index-in-node=\"0\"\u003eLocație Instalare\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,23,1,0\"\u003eInterior\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,24,0,0\"\u003e\u003cb data-path-to-node=\"2,24,0,0\" data-index-in-node=\"0\"\u003eInstalare\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,24,1,0\"\u003eMontat pe perete \/ Pe podea \/ Suprapus (Stack) \/ În rack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,25,0,0\"\u003e\u003cb data-path-to-node=\"2,25,0,0\" data-index-in-node=\"0\"\u003eCertificări\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"2,25,1,0\"\u003eIEC62619 \/ UL1973 \/ UN38.3 \/ CE \/ UKCA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/anfi-power.ro\/wp-content\/uploads\/2025\/07\/Datasheet-LV-series-Flex-L3-STELTEC_250602_140652-6.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFisa Tehnica\u003c\/a\u003e\u003c\/h3\u003e","brand":"ECOSOLEX","offers":[{"title":"Default Title","offer_id":57372417294710,"sku":"sku-2218","price":3271.0,"currency_code":"RON","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0778\/4775\/7105\/files\/a4fd3f402903596b6b470bbda44e7c64.webp?v=1772117408","url":"https:\/\/gpisolarconsult.ro\/products\/baterie-ecosolex-esr-l5000a","provider":"gpiconsult","version":"1.0","type":"link"}